NES-50W series Efficient single switching power supply
Features:·universal AC input
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Year warranty
|
Model |
NES-50-5 |
NES-50-12 |
NES-50-15 |
NES-50-24 |
||||
|
output |
DC voltage |
5V |
12V |
15V |
24V |
|||
|
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
||||
|
Rated current |
10A |
4.2A |
3.4A |
2.1A |
||||
|
Current range |
0~10A |
0~4.2A |
0~3.4A |
0~2.1A |
||||
|
Rated power |
50W |
50.4W |
51W |
50.4W |
||||
|
Ripple&noise |
80mvp-p |
100mvp-p |
120mvp-p |
120mvp-p |
||||
|
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
||||
|
input |
Voltage range |
90~264VAC,125~373VDC |
||||||
|
frequency |
47~63HZ |
|||||||
|
AC current |
1.2A/115VAC,0.6A/230VAC |
|||||||
|
efficiency |
79% |
82% |
82% |
84% |
||||
|
Inrush current |
Cold start current 18A/115VAC,36A/230VAC |
|||||||
|
Leakage current |
< 2mA/240VAC |
|||||||
|
protection |
Over load |
Rated output power110%~150% start over load protection |
||||||
|
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||||
|
over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
||||
|
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||||
|
environment |
Working temp,humidity |
-20℃~+60℃,20%~90%RH |
||||||
|
Storagetemp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
|||||||
|
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
|||||||
|
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||
|
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
|||||||
|
Fitstandard |
Safety standard |
Fit UL1012 |
||||||
|
EMC standard |
符合EN55022,CLASSA |
|||||||
|
others |
Dimension |
111*78*36mm (L*W*H) |
||||||
|
Weight/packing |
0.27kg/50pcs/14.5kg/0.027m3/0.96CUFT |
|||||||
|
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
|||||||