HLG-80W series Full function adjustable waterproof power supply
Features:·universal AC input
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3Year warranty
Model |
HLG-80-12 |
HLG-80-15 |
HLG-80-24 |
HLG-80-36 |
HLG-80-48 |
|
output |
DC voltage |
12V |
15V |
24V |
36V |
48V |
Constant current region |
7.2~12V |
9~15V |
14.4~24V |
21.6~36V |
28.8~48V |
|
Rated current |
5A |
5A |
3.4A |
2.3A |
1.7A |
|
Rated power |
60W |
75W |
81.6W |
82.8W |
81.6W |
|
Ripple&noise |
150mvp-p |
150mvp-p |
150mvp-p |
200mvp-p |
200mvp-p |
|
Voltage ADJ range |
10.8~13V |
13.5~17V |
22~27V |
33~40V |
43~53V |
|
Current ADJ range |
Can be adjusted by internal potentiometer or through output cable |
|||||
|
3~5A |
3~5A |
2.04~3.4A |
1.38~2.3A |
1.02~1.7A |
|
input |
Voltage range |
90~264VAC,47~63HZ ,127~370VDC |
||||
AC current |
0.8A/115VAC,0.4A/230VAC |
|||||
Power factor |
PF>0.95/230VAC,PF>0.98/115VAC Start overload protection |
|||||
efficiency |
88% |
89% |
90% |
91% |
91% |
|
Inrush current |
Cold start current 35A/115VAC,70A/230VAC |
|||||
Leakage current |
< 0.75mA/240VAC |
|||||
protection |
Over current |
95%~108% |
||||
protection type :Constant current limiting ,auto-recovery after fault condition is removed |
||||||
Short circuit |
Hiccup mode,recovers automatically after fault condition is remove |
|||||
Over voltage |
14~17V |
18~21V |
28~34V |
41~46V |
54~60V |
|
protection type:Shut down o/p voltage re-power on to recover |
||||||
Over temperature |
100℃±10℃(RTH2) |
|||||
protection type:Shut down o/p voltage re-power on to recover |
||||||
environment |
Working temp,humidity |
-20℃~+60℃,20%~90%RH |
||||
Storagetemp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
|||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
|||||
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
|||||
Fitstandard |
Safety standard |
Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved |
||||
EMC standard |
Fit EN55015,EN61000-3-2 ClassC(>60%load):EN61000-3-3 |
|||||
others |
Dimension |
174*63*39mm (L*W*H) |
||||
Weight/packing |
0.84kg/20pcs/17.5kg/0.026m3/0.91CUFT |
|||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |